micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C
M. Ruf, and H. Steeb. Dataset, (2020)Related to: Lissa, S.; Ruf, M.; Steeb, H. & Quintal, B. (2020). Effects of crack roughness on attenuation caused by squirt flow in Carrara marble. SEG Technical Program Expanded Abstracts 2020, 2439-2443. doi: 10.1190/segam2020-3427789.1.
DOI: 10.18419/darus-754
Abstract
micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following thermal treatment to initiate cracks: Starting at room temperature (20°C), the sample was heated up with a rate of 3 K/min to 600°C. After a holding time of 2 hours at 600°C, the sample was subsequently slowly cooled down in the closed oven back to room temperature (20°C).
Ruf, Matthias/University of Stuttgart, Institute of Applied Mechanics (CE), Steeb, Holger/University of Stuttgart, Institute of Applied Mechanics (CE) & SimTech
Related to: Lissa, S.; Ruf, M.; Steeb, H. & Quintal, B. (2020). Effects of crack roughness on attenuation caused by squirt flow in Carrara marble. SEG Technical Program Expanded Abstracts 2020, 2439-2443. doi: 10.1190/segam2020-3427789.1
%0 Generic
%1 ruf2020microxrct
%A Ruf, Matthias
%A Steeb, Holger
%D 2020
%K darus mult ubs_10002 ubs_10021 ubs_20002 ubs_20019 ubs_30024 ubs_30165 ubs_40399 unibibliografie
%R 10.18419/darus-754
%T micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C
%X micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following thermal treatment to initiate cracks: Starting at room temperature (20°C), the sample was heated up with a rate of 3 K/min to 600°C. After a holding time of 2 hours at 600°C, the sample was subsequently slowly cooled down in the closed oven back to room temperature (20°C).
@misc{ruf2020microxrct,
abstract = {micro-XRCT data set (projections and reconstructed images) of a Carrara marble core with a diameter of 5 mm. The sample was extracted with a water-cooled diamond drill from a bigger sample with a diameter of 30 mm and a length of 80 mm which was before subjected to following thermal treatment to initiate cracks: Starting at room temperature (20°C), the sample was heated up with a rate of 3 K/min to 600°C. After a holding time of 2 hours at 600°C, the sample was subsequently slowly cooled down in the closed oven back to room temperature (20°C).},
added-at = {2022-06-09T19:15:45.000+0200},
affiliation = {Ruf, Matthias/University of Stuttgart, Institute of Applied Mechanics (CE), Steeb, Holger/University of Stuttgart, Institute of Applied Mechanics (CE) & SimTech},
author = {Ruf, Matthias and Steeb, Holger},
biburl = {https://puma.ub.uni-stuttgart.de/bibtex/2ebe914f3f866c6435c9d06188252b107/unibiblio},
doi = {10.18419/darus-754},
howpublished = {Dataset},
interhash = {9867d42e2d6b8ef8bfb2b63952dae878},
intrahash = {ebe914f3f866c6435c9d06188252b107},
keywords = {darus mult ubs_10002 ubs_10021 ubs_20002 ubs_20019 ubs_30024 ubs_30165 ubs_40399 unibibliografie},
note = {Related to: Lissa, S.; Ruf, M.; Steeb, H. & Quintal, B. (2020). Effects of crack roughness on attenuation caused by squirt flow in Carrara marble. SEG Technical Program Expanded Abstracts 2020, 2439-2443. doi: 10.1190/segam2020-3427789.1},
orcid-numbers = {Ruf, Matthias/0000-0003-0299-5921, Steeb, Holger/0000-0001-7602-4920},
timestamp = {2023-11-03T12:07:53.000+0100},
title = {micro-XRCT data set of Carrara marble with artificially created crack network: slow cooling down from 600°C},
year = 2020
}