Fault Diagnosis for Power Converter in SRM Drives Based on Current Prediction. IEEE Transactions on Industrial Electronics, (69)12:13576--13585, 2022. [PUMA: Asymmetric_half-bridge_converter_(AHBC) Current_measurement Fault_diagnosis Phase_measurement Sensor_systems Sensors Transistors Windings diagnosis_scheme hp_iew multiple_faults reconstruction_of_current_sensors switched_reluctance_motor_(SRM)]
Measurement of Transient Overvoltages by Capacitive Electric Field Sensors.. Sensors, (24)5:1357, 2024. [PUMA: Capacitive Electric Field Measurement Overvoltages Sensors Transient by of]
Using capacitive electric field sensors to measure transient overvoltages: a case study.. August 2023. [PUMA: Using a capacitive case electric field measure overvoltages: sensors study to transient]
System-safety in the application of adaptive load-bearing structures. 2019 IEEE Annual Reliability and Maintainability Symposium (RAMS), January 28-31, 2019, Orlando, FL, 2019. [PUMA: actuators, adaptive buildings, reliability, safety, sensors sobek stress, systems,]
Integrating Ionic Electroactive Polymer Actuators and Sensors into Adaptive Building Skins : Potentials and Limitations. Frontiers in Built Environment, (6):95, Frontiers, 2020. [PUMA: 2020 Integrating Ionic actuators adaptive and bauernhansl biomat building dahy electroactive itke kolaric neuhaus petrs polymer potentials sensors siegert skins tahouni zahiri]
PSSST! The Privacy System for Smart Service Platforms: An Enabler for Confidable Smart Environments. In Muthu Ramachandran, Robert Walters, Gary Wills, Víctor Méndez Muñoz, and Victor Chang (Eds.), Proceedings of the 4ᵗʰ International Conference on Internet of Things, Big Data and Security, (1):57–68, SciTePress, Heraklion, May 2019. [PUMA: Internet_of_Things access_control actuators privacy sensors smart_service_platform stream_processing]
Sensors and Sensing used for Non-Conventional PD-Detection. 2006. [PUMA: Non-Conventional PD-Detection Sensing Sensors]
Sensitivity Evaluation of Different Types of PD Sensors for UHF-PD-Measurements. 2010. [PUMA: PD-Measurement Sensitivity Sensors UHF] URL
On-site Partial Discharge Measurement in Power Transformers by UHF Sensors. 2011. [PUMA: Discharge Measurement On-site Partial Power Sensors Transformers UHF]
Design and Monitoring of Cold Bent Lamination-Stabilised Glass. Investigated by Applying Fibre Optic Sensors. In Jan Knippers (Eds.), Forschungsberichte aus dem Institut für Tragkonstruktionen und Konstruktives Entwerfen, (39)Institut für Tragkonstruktionen und Konstruktives Entwerfen, ITKE, Stuttgart, Germany, 2015. [PUMA: 2015 applying bent cold design diss dissertation engineering fibre fildhuth forschungsbericht from:petraheim glass investtigated itke lamination lamination-stabilised monitoring optic sensors stabilised]
Design and Monitoring of Cold Bent Lamination-Stabilised Glass. Investigated by Applying Fibre Optic Sensors. In Jan Knippers (Eds.), Forshungsberichte aus dem Institut für Tragkonstruktionen und Konstruktives Entwerfen, (39)Institut für Tragkonstruktionen und Konstruktives Entwerfen, ITKE, Stuttgart, Germany, 2015. [PUMA: 2015 applying bent cold design dissertation engineering fibre fildhuth forschungsbericht glass investtigated itke lamination lamination-stabilised monitoring optic sensors stabilised]
Impact of Rogowski sensors on the EMC performance of medium voltage power substations. 203-208, IEEE, Piscataway, NJ, 2015. [PUMA: EMC Rogowski Sensors medium performance power substations voltage] URL
A Generic Platform for Safety-critical Applications in General Aviation. IEEE 32th Aerospace Conference, Big Sky, Montana, March 2011. [PUMA: Aerospace_electronics Aircraft Distributed_databases Gallium InProceedings Redundancy Safety Topology actuator actuators aerial_work_operation aerospace_control aerospace_safety automatic_flight_control_system avionics electronic_control_systems fault-tolerant_computing_core_network fault_tolerant_computing general_aviation generic_components hardware_components ils safety-critical_applications sensor sensors]
Quantitative Analysis of the Sensitivity of UHF Sensor Positions on a 420 kV Power Transformer Based on Electromagnetic Simulation. Energies 2020, December 2019. [PUMA: PD UHF acceptance discharge evaluation monitoring partial positioning power sensitivity sensor sensors tests transformers] URL
Partial Discharge Monitoring of Power Transformers by UHF Sensors. October 2016. [PUMA: Discharge Monitoring Partial Power Sensors Transformers UHF] URL
System-safety in the application of adaptive load-bearing structures. 2019 IEEE Annual Reliability and Maintainability Symposium (RAMS), January 28-31, 2019, Orlando, FL, 2019. [PUMA: actuators, adaptive buildings, reliability, safety, sensors stress, systems,]
Calibration Proposal for UHF Partial Discharge Measurements at Power Transformers. Energies, (12)162019. [PUMA: IEC60270 PD UHF acceptance-tests antenna-factorsend:unibiblio calibration diagnosis monitoring partial-discharge power-transformers sensors] URL
Application of UHF Sensors for PD Measurement at Power Transformers. IEEE Transactions on Dielectrics and Electrical Insulation, (24)1:331-339, 2017. [PUMA: Power Sensors Transformers UHF] URL
MITT Manipulator System for Minimal Invasive Surgery, Paper Nr. 388-807 for IASTEDInternational Conference on Intelligent Systems and Control,Salzburg, 25.-27.7.2003: MITT Manipulator System for Minimal Invasive Surgery, Paper Nr. 388-807 for IASTEDInternational Conference on Intelligent Systems and Control,Salzburg, 25.-27.7.2003. --, 2003. [PUMA: ISW Mechatronic advanced and control medical orientation position robotics, sensors system,]