A new catheter design using needle electrode for subendocardial RF ablation of ventricular muscles: finite element analysis and in vitro experiments.

, , , , , , and . IEEE Trans. Biomed. Engineering, 47 (1): 23-31 (2000)

Please choose a person to relate this publication to

To differ between persons with the same name, the academic degree and the title of an important publication will be displayed. You can also use the button next to the name to display some publications already assigned to the person.

Univ. -Prof. Dr. -Ing. Krzysztof Rudion University of Stuttgart

Zeitreihenbasierte Modellierung des Ladebedarfs batterie-elektrischer Lkw für die probabilistische Netzplanung, and . ETG Kongress 2023 : Die Energiewende beschleunigen, 170, page 969-976. Berlin, VDE Verlag, (2023)
Zeitreihenbasierte Modellierung des Ladebedarfs batterie-elektrischer Lkw für die probabilistische Netzplanung, and . ETG Kongress 2023 : Die Energiewende beschleunigen, 170, page 969-976. Berlin, VDE Verlag, (2023)Blindleistungssteuerung von dezentralen Erzeugungsanlagen zur Verlustreduktion in 110 kV-Netzen mittels linearer Optimierung, and . ETG Kongress 2023 : Die Energiewende beschleunigen, 170, page 267-272. Berlin, VDE Verlag, (2023)
 

Other publications of authors with the same name

Using electrical impedance to predict catheter-endocardial contact during RF cardiac ablation., , , , , and . IEEE Trans. Biomed. Engineering, 49 (3): 247-253 (2002)Temperature measurement within myocardium during in vitro RF catheter ablation., , , , , and . IEEE Trans. Biomed. Engineering, 47 (11): 1518-1524 (2000)Modeling bipolar phase-shifted multielectrode catheter ablation., , , , , , and . IEEE Trans. Biomed. Engineering, 49 (1): 10-17 (2002)Noncontact radio-frequency ablation for obtaining deeper lesions., , , , , , and . IEEE Trans. Biomed. Engineering, 50 (2): 218-223 (2003)Error analysis of tissue resistivity measurement., , , , , , , , and . IEEE Trans. Biomed. Engineering, 49 (5): 484-494 (2002)Guidelines for predicting lesion size at common endocardial locations during radio-frequency ablation., , , , , and . IEEE Trans. Biomed. Engineering, 48 (2): 194-201 (2001)Three-dimensional finite-element analyses for radio-frequency hepatic tumor ablation., , , , , , , , and . IEEE Trans. Biomed. Engineering, 49 (1): 3-9 (2002)FEM analysis of predicting electrode-myocardium contact from RF cardiac catheter ablation system impedance., , , , , and . IEEE Trans. Biomed. Engineering, 49 (6): 520-526 (2002)Lesion size estimator of cardiac radiofrequency ablation at different common locations with different tip temperatures., , , , and . IEEE Trans. Biomed. Engineering, 51 (10): 1859-1864 (2004)In-vivo measurement of swine myocardial resistivity., , , , , , , , and . IEEE Trans. Biomed. Engineering, 49 (5): 472-483 (2002)