Inproceedings,

Leakage current reduction for a double-leg boost-converter by switching transition synchronisation

, , , , and .
The 9th International Conference on Power Electronics, Machines and Drives (PEMD 2018), 2019, 17, page 3789-3792. Stevenage, IET, (2019)
DOI: 10.1049/joe.2018.8128

Abstract

With wide-bandgap transistors, the leakage current through the parasitic transistor to heat sink capacitance is increased with the operation at higher switching transition voltage slopes. This study presents a modulation synchronisation method for a double-leg boost converter to reduce these leakage currents. Having a similar leakage current path, the transistors turn-on transition of one leg is synchronised on the turn-off transition of the second leg.

Tags

Users

  • @unibiblio
  • @ilea