The resolution of the reconstructed wave by a phase-retrieval method using a volume-speckle field depends on the aperture defined by the size of the CCD array. The use of a larger aperture is introduced by measuring the speckle field at two different positions in the transverse plane and stitching the measurements together. Improvements in the quality of reconstructions are demonstrated experimentally and by computer simulations. Undesirable effects of camera tilt on the quality of reconstructions from synthetic aperture intensity measurements are experimentally observed and corrected.
%0 Journal Article
%1 Almoro:07
%A Almoro, P.
%A Pedrini, G.
%A Osten, W.
%D 2007
%I OSA
%J Opt. Lett.
%K ito kom reviewed
%N 7
%P 733--735
%R 10.1364/OL.32.000733
%T Aperture synthesis in phase retrieval using a volume-speckle field
%U http://ol.osa.org/abstract.cfm?URI=ol-32-7-733
%V 32
%X The resolution of the reconstructed wave by a phase-retrieval method using a volume-speckle field depends on the aperture defined by the size of the CCD array. The use of a larger aperture is introduced by measuring the speckle field at two different positions in the transverse plane and stitching the measurements together. Improvements in the quality of reconstructions are demonstrated experimentally and by computer simulations. Undesirable effects of camera tilt on the quality of reconstructions from synthetic aperture intensity measurements are experimentally observed and corrected.
@article{Almoro:07,
abstract = {The resolution of the reconstructed wave by a phase-retrieval method using a volume-speckle field depends on the aperture defined by the size of the CCD array. The use of a larger aperture is introduced by measuring the speckle field at two different positions in the transverse plane and stitching the measurements together. Improvements in the quality of reconstructions are demonstrated experimentally and by computer simulations. Undesirable effects of camera tilt on the quality of reconstructions from synthetic aperture intensity measurements are experimentally observed and corrected.},
added-at = {2019-05-07T12:07:16.000+0200},
author = {Almoro, P. and Pedrini, G. and Osten, W.},
biburl = {https://puma.ub.uni-stuttgart.de/bibtex/27e0ede9448abcf0b9a7e3f00da779dcc/vogelfrau},
doi = {10.1364/OL.32.000733},
interhash = {26d70d3d372ab2b4f4fd0c6e610250bd},
intrahash = {7e0ede9448abcf0b9a7e3f00da779dcc},
journal = {Opt. Lett.},
keywords = {ito kom reviewed},
month = apr,
number = 7,
pages = {733--735},
publisher = {OSA},
timestamp = {2019-05-07T10:07:16.000+0200},
title = {Aperture synthesis in phase retrieval using a volume-speckle field},
url = {http://ol.osa.org/abstract.cfm?URI=ol-32-7-733},
volume = 32,
year = 2007
}