Frequency Range of UHF PD Measurements in Power Transformers.. Energies 2023, (16)3January 2023. [PUMA: Frequency Measurements PD Power Range Transformers UHF in of]
Condition Assessment of Power Transformers by UHF PD Measurements. 2022. [PUMA: Assessment Condition Measurements PD Power Transformers UHF by of]
Increase of Reliability of Power Transformers by Calibrated UHF PD Measurements in FAT and SAT.. October 2021. [PUMA: Calibrated FAT Increase Measurements PD Power Reliability SAT. Transformers UHF and by in of]
Influence of Dielectric Window on the Performance of Window-type UHF PD Sensors. 561, 2020. [PUMA: Dielectric Influence PD Performance Sensorssend:unibiblio UHF Window Window-type of on thesend:unibiblio]
Quantitative Analysis of the Sensitivity of UHF Sensor Positions on a 420 kV Power Transformer Based on Electromagnetic Simulation. Energies 2020, (13)32020. [PUMA: 420 Analysis Based Electromagnetic Positions Power Quantitative Sensitivity Sensor Simulationsend:unibiblio Transformer UHF kV]
Proposal of a Calibration Methodology of UHF Partial Discharge Measurements for Power Transformers. 2020. [PUMA: Calibration Discharge Measurements Methodology Partial Power Proposal Transformerssend:unibiblio UHF a for of]
Partial Discharge Analysis in Gas-Insulated HVDC Systems Using Conventional and Non-Conventional Methods. 2020. [PUMA: 60270 GIS HVDC IEC PD UHF free high imaging measurement metallic moving particle protrusion speedsend:unibiblio] URL
Calibration of UHF PD Measurements for Power Transformers. 2019. [PUMA: Calibration Measurements PD Power Transformers UHF]
Attenuation of UHF Signals in a 420 kV Power Transformer based on Experiments and Simulation. 2019. [PUMA: 420 Power Signals Simulation Transformer UHF kV]
Calibration of UHF Partial Discharge Measurements for Power Transformers. 2019. [PUMA: Calibration Discharge Measurements Partial Power Transformers UHF]
UHF Partial Discharge Measurement for Acceptance Tests of Power Transformers. 2019. [PUMA: Acceptance Discharge Measurement Partial Power Tests Transformers UHF]
Improvement of acoustic detection and localization accuracy by sensitive electromagnetic PD measurements under oil in the UHF range. 2005. [PUMA: PD UHF accuracy acoustic detection electromagnetic localization measurements oil range sensitive] URL
Electromagnetic (UHF) PD Diagnosis of GIS, Cable Accessories and Oil-paper Insulated Power Transformers for Improved PD Detection and Localization. 2006. [PUMA: Accessories Assessment Cable Condition GIS On-site PD-Measurement Power Transformers UHF] URL
Detection of Partial Discharges in Power Transformers using UHF PD Measurements and Acoustic Measurements. 2007. [PUMA: Acoustic Detection Discharges Measurement PD Partial Power Transformers UHF] URL
Performance Check and Sensitivity Verification for UHF PD measurements on power transformers. 2007. [PUMA: Check PD Performance Sensitivity UHF Verification measurements power transformers] URL
UHF Partial Discharge Diagnosis of Plug-in Cable Terminations. 2007. [PUMA: Cable Diagnosis Discharge Partial Plug-in Terminations UHF]
Sensitivity of UHF PD Measurements in Power Transformers. IEEE Transactions on Dielectrics and Electrical Insulation, (15)6:1553-1558, 2008. [PUMA: Measurements PD Power Sensitivity Transformers UHF]
Simulation of UHF PD wave propagation in plug-in cable terminations. 547-550, 2008. [PUMA: PD UHF cable plug-in propagation terminations wave] URL
Wide and narrow band PD detection in plug-in cable connectors in the UHF range. 2008. [PUMA: Cable UHF diagnostics discharge narrowband on-line partial termination wide] URL
Fundamental Differences of the PD Measurement according to IEC 60270 and in UHF range. 2008. [PUMA: (GIS) IEC IEC60270 UHF discharge gas insulated measurement of partial sensitivity standard switchgear the verification] URL