Publications

Rouven Berkemeier, R. Bach, and Stefan Tenbohlen. 3D-Localization of Partial Discharge in XLPE-Cable-Terminations using UHF-Sensors.. August 2023. [PUMA: in using Partial of 3D-Localization UHF-Sensors XLPE-Cable-Terminations Discharge]

Stefan Hoek, Uwe Riechert, Thomas Strehl, Stefan Tenbohlen, and Kurt Feser. A New Procedure for Partial Discharge Localization in Gas-Insulated Switchgear in Frequency Domain. 2005. [PUMA: Gas-Insulated Partial Switchgear Domain Localization Discharge Frequency] URL

Thomas Klein, Denis Denissov, Wolfgang Köhler, and Stefan Tenbohlen. Application of UHF method for on-line PD diagnostics of cable terminations. 2008. [PUMA: check (UHF) termination frequency ultra-high On-line diagnostics sensitivity discharge cable partial (PD)] URL

Joszef J. Osztermayer, Enzo Cardillo, Sacha Markalous, René Wimmer, M. Lenz, Stefan Hoek, and Kurt Feser. Asset Management Based on Improved Online Monitoring Systems Applied to a 110/380 kV Substation. 2003. [PUMA: monitoring Acoustic Electric Hot-spot Managementdecision-making system PD Asset-Management function online Transfer discharge partial temperature Power] URL

Manuel Wild, Stefan Tenbohlen, Edward Gulski, and Rogier Jongen. Basic Aspects of Partial Discharge On-site Testing of Long Length Transmission Power Cables. IEEE Transactions on Dielectrics and Electrical Insulation, (24)2:1077-1087, April 2017. [PUMA: Partial Discharge]

Martin Siegel, and Stefan Tenbohlen. Calibration of UHF Partial Discharge Measurement for Power Transformers and a Comparison to the Calibration of Electrical PD Measurement. 2016. [PUMA: Monitoring UHF Partial Electromagnetic Calibration Transformers Discharge IEC60270 Power] URL

Stefan Tenbohlen, Martin Siegel, Michael Beltle, and Sebastian Coenen. Calibration of UHF Partial Discharge Measurements for Power Transformers. 2019. [PUMA: UHF Measurements Partial Calibration Transformers Discharge Power]

Chandra Prakash Beura, Philipp Wenger, E. Tozan, Michael Beltle, and Stefan Tenbohlen. Classification of Partial Discharge Sources in HVDC Gas Insulated Switchgear using Neural Networks. November 2022. [PUMA: Networks Sources in using Switchgear Discharge HVDC Insulated Classification Partial of Gas Neural]

Benjamin Adam, and Stefan Tenbohlen. Classification of Superimposed Partial Discharge Patterns.. Energies 2021, (14)2144April 2021. [PUMA: Superimposed Patterns. Classification Partial of Discharge]

Martin Siegel, and Stefan Tenbohlen. Comparison between Electrical and UHF PD Measurement concerning Calibration and Sensitivity for Power Transformers. 2014. [PUMA: Transformer Sensitivity UHF Partial Calibration Apparent Discharge Charge (PD) Power] URL

Manuel Wild, Stefan Tenbohlen, and B. Quak. Comparison of Partial Discharge Behavior with Alternating Current and Damped Alternating Current at Different Frequencies. 513-516, 2014. [PUMA: Comparison Partial Alternating Behavior Frequencies Current Damped Discharge Different] URL

Franz Streibl, Stefan Tenbohlen, Jörg Hartmann, and Michael Zerrer. Derating of Ceramic Capacitors during Electrostatic Discharges. 187-190, 2008. [PUMA: Human Compatibility Discharge Electro-static HBM ESD CeramicCapacitor Electromagnetic Model Resonance Capacitance EMC Frequency Body] URL

Martin Siegel, and Stefan Tenbohlen. Design of an Oil-filled GTEM Cell for the Characterization of UHF PD Sensors. 2014. [PUMA: Measurement Routine Discharge cell Monitoring UHF PD GTEM Partial oil-filled Test Factor Transformers Diagnosis Antenna (PD) Power] URL

Stefan Hoek, Sebastian Coenen, M. Bornowski, and Stefan Tenbohlen. Fundamental Differences of the PD Measurement according to IEC 60270 and in UHF range. 2008. [PUMA: standard IEC measurement (GIS) IEC60270 insulated the UHF of switchgear gas sensitivity discharge partial verification] URL

Edward Gulski, W. Koltunowicz, T. Ariaans, G. Behrmann, Rogier Jongen, F. Garnacho, S. Kornhuber, S. Ohtsuka, Frank Petzold, M. Sanchez-Uran, K. Siodla, and Stefan Tenbohlen. Guidelines for partial discharge detection using conventional (IEC 60270) and unconventional methods. Cigre Technical Brochure 662, August 2016. [PUMA: detection discharge partial]

Edward Gulski, W. Koltunowicz, T. Ariaans, G. Behrmann, Rogier Jongen, F. Garnacho, Stefan Kornhuber, S. Ohtsuka, Frank Petzold, M. Sanchez-Uran, K. Siodla, and Stefan Tenbohlen. Guidelines for partial discharge detection using conventional (IEC 60270) and unconventional methods. Electra, 288:24-29, 2016. [PUMA: detection IEC discharge partial 60270]

Edward Gulski, T. Strehl, M. Muhr, Stefan Tenbohlen, S. Meijer, M.D. Judd, R. Bodega, E. Lemke, R.A. Jongen, Sebastian Coenen, B. Larzelere, M. Hanai, and P. Agoris. Guidelines for Unconventional Partial Discharge Measurements. Electra, 253:91-95, December 2010. [PUMA: Measurements Partial Unconventional Discharge]

Chuxuan He, Stefan Tenbohlen, and Jonas Bux. Improvement of a Loop Antenna for Partial Discharge Measurement of Inverter-fed Hairpin Motors.. August 2023. [PUMA: a Loop Measurement for Motors Discharge Inverter-fed Hairpin Improvement Partial of Antenna]

Jackelyne Aragón-Patil, Markus Fischer, and Stefan Tenbohlen. Improvement of interpretation of dissolved gas analysis for power transformers. 91-97, 2007. [PUMA: Sugeno Fault Discharge PRPD Analysis Dissolved Partial Fuzzy Gas PD-Stressing Detection Logic] URL

Chuxuan He, Chandra Prakash Beura, and Stefan Tenbohlen. Investigation of Partial Discharge Activity in the Slot of a Hairpin-wound Stator. 2020. [PUMA: miniaturized PDIV discharges test inception hairpinwound PD discharge inverterfed block stator machines partial] URL