3D-Localization of Partial Discharge in XLPE-Cable-Terminations using UHF-Sensors.. August 2023. [PUMA: in using Partial of 3D-Localization UHF-Sensors XLPE-Cable-Terminations Discharge]
A New Procedure for Partial Discharge Localization in Gas-Insulated Switchgear in Frequency Domain. 2005. [PUMA: Gas-Insulated Partial Switchgear Domain Localization Discharge Frequency] URL
Application of UHF method for on-line PD diagnostics of cable terminations. 2008. [PUMA: check (UHF) termination frequency ultra-high On-line diagnostics sensitivity discharge cable partial (PD)] URL
Asset Management Based on Improved Online Monitoring Systems Applied to a 110/380 kV Substation. 2003. [PUMA: monitoring Acoustic Electric Hot-spot Managementdecision-making system PD Asset-Management function online Transfer discharge partial temperature Power] URL
Basic Aspects of Partial Discharge On-site Testing of Long Length Transmission Power Cables. IEEE Transactions on Dielectrics and Electrical Insulation, (24)2:1077-1087, April 2017. [PUMA: Partial Discharge]
Calibration of UHF Partial Discharge Measurement for Power Transformers and a Comparison to the Calibration of Electrical PD Measurement. 2016. [PUMA: Monitoring UHF Partial Electromagnetic Calibration Transformers Discharge IEC60270 Power] URL
Calibration of UHF Partial Discharge Measurements for Power Transformers. 2019. [PUMA: UHF Measurements Partial Calibration Transformers Discharge Power]
Classification of Partial Discharge Sources in HVDC Gas Insulated Switchgear using Neural Networks. November 2022. [PUMA: Networks Sources in using Switchgear Discharge HVDC Insulated Classification Partial of Gas Neural]
Classification of Superimposed Partial Discharge Patterns.. Energies 2021, (14)2144April 2021. [PUMA: Superimposed Patterns. Classification Partial of Discharge]
Comparison between Electrical and UHF PD Measurement concerning Calibration and Sensitivity for Power Transformers. 2014. [PUMA: Transformer Sensitivity UHF Partial Calibration Apparent Discharge Charge (PD) Power] URL
Comparison of Partial Discharge Behavior with Alternating Current and Damped Alternating Current at Different Frequencies. 513-516, 2014. [PUMA: Comparison Partial Alternating Behavior Frequencies Current Damped Discharge Different] URL
Derating of Ceramic Capacitors during Electrostatic Discharges. 187-190, 2008. [PUMA: Human Compatibility Discharge Electro-static HBM ESD CeramicCapacitor Electromagnetic Model Resonance Capacitance EMC Frequency Body] URL
Design of an Oil-filled GTEM Cell for the Characterization of UHF PD Sensors. 2014. [PUMA: Measurement Routine Discharge cell Monitoring UHF PD GTEM Partial oil-filled Test Factor Transformers Diagnosis Antenna (PD) Power] URL
Fundamental Differences of the PD Measurement according to IEC 60270 and in UHF range. 2008. [PUMA: standard IEC measurement (GIS) IEC60270 insulated the UHF of switchgear gas sensitivity discharge partial verification] URL
Guidelines for partial discharge detection using conventional (IEC 60270) and unconventional methods. Cigre Technical Brochure 662, August 2016. [PUMA: detection discharge partial]
Guidelines for partial discharge detection using conventional (IEC 60270) and unconventional methods. Electra, 288:24-29, 2016. [PUMA: detection IEC discharge partial 60270]
Guidelines for Unconventional Partial Discharge Measurements. Electra, 253:91-95, December 2010. [PUMA: Measurements Partial Unconventional Discharge]
Improvement of a Loop Antenna for Partial Discharge Measurement of Inverter-fed Hairpin Motors.. August 2023. [PUMA: a Loop Measurement for Motors Discharge Inverter-fed Hairpin Improvement Partial of Antenna]
Improvement of interpretation of dissolved gas analysis for power transformers. 91-97, 2007. [PUMA: Sugeno Fault Discharge PRPD Analysis Dissolved Partial Fuzzy Gas PD-Stressing Detection Logic] URL
Investigation of Partial Discharge Activity in the Slot of a Hairpin-wound Stator. 2020. [PUMA: miniaturized PDIV discharges test inception hairpinwound PD discharge inverterfed block stator machines partial] URL