Publications

Denis Denissov, Wolfgang Köhler, Stefan Tenbohlen, Ruben Grund, and Thomas Klein. Wide and narrow band PD detection in plug-in cable connectors in the UHF range. 2008. [PUMA: Cable narrowband UHF on-line diagnostics wide termination discharge partial] URL

Martin Siegel, and Stefan Tenbohlen. Vorschlag zur Kalibrierung der UHF Teilentladungsmessung an Leistungstransformatoren. 660-665, 2016. [PUMA: Kalibrierung UHF Teilentladungsmessung] URL

Takahiro Umemoto, and Stefan Tenbohlen. Validations of simulation of UHF electromagnetic wave propagation in an oil-filled tank by time-domain measurements. IET Generation, Transmission & Distribution, (13)9:1646--1652, Institution of Engineering and Technology (IET), May 2018. [PUMA: from:annettegugel Wave UHF Propagation Electromagnetic] URL

Michael Beltle, Chandra Prakash Beura, Martin Siegel, and Stefan Tenbohlen. UHF Sensor Placement on Power Transformers for PD Monitoring. 2019. [PUMA: Positioning Condition Monitoring Transformer UHF PD Assessment Sensor Power] URL

Stefan Tenbohlen, and Martin Siegel. UHF Partial Discharge Measurement for Acceptance Tests of Power Transformers. 2019. [PUMA: Acceptance UHF Partial Measurement Transformers Discharge Power Tests]

Denis Denissov, Ruben Grund, Thomas Klein, Wolfgang Köhler, and Stefan Tenbohlen. UHF Partial Discharge Diagnosis of Plug-in Cable Terminations. 2007. [PUMA: Cable Terminations UHF Partial Diagnosis Plug-in Discharge]

Uwe Schichler, W. Koltunowicz, David Gautschi, A. Girodet, H. Hama, J. Lopez-Roldan, S. Neuhold, C. Neumann, S. Okabe, J. Pearson, R. Pietsch, Uwe Riechert, and Stefan Tenbohlen. UHF Partial Discharge Detection System for GIS: Application Guide for Sensitivity Verification. Cigre Technical Brochure 654, April 2016. [PUMA: UHF Partial Discharge]

Sebastian Coenen, Andreas Müller, Michael Beltle, and Stefan Kornhuber. UHF and Acoustic Partial Discharge Localisation in Power Transformers. 2011. [PUMA: UHF Acoustic Partial Transformers Localisation Discharge Power] URL

Philipp Wenger, Michael Beltle, Stefan Tenbohlen, and Uwe Riechert. TE-Charakterisierung frei beweglicher Partikel in HVDC-GIS mittels UHF-Messtechnik und Hochgeschwindigkeitskamera-Aufnahmen. 10-15, 2018. [PUMA: TE GIS Highspeedkamerasend:unibiblio Charakterisierung UHF Partikel HVDC]

Stefan Tenbohlen, Martin Siegel, Michael Beltle, and Martin Reuter. Suitability of Ultra High Frequency Partial Discharge Measurement for Quality Assurance and Testing of Power Transformers. 2013. [PUMA: Testing Routine Monitoring UHF PD Measurementfor Partial oil-filled Factor Discharges Transformers Diagnosis Antenna GTEMcell Power] URL

Philipp Wenger, S. Abdul Madhar, and Stefan Tenbohlen. Simultaneous Electrical, UHF, Current and Optical PD Measurement on Floating Potential und DC Stress. 2019. [PUMA: Measurement Potential Optical Stress Floating UHF PD Electrical Current Simultaneous DC]

S. Abdul Madhar, Philipp Wenger, and Michael Beltle. Simultaneous Electrical and UHF Measurement of DC-PD from Point-Plane Defect. 2019. [PUMA: UHF Electrical Measurement Point-Plane Defect DC-PD Simultaneous]

Denis Denissov, Wolfgang Köhler, Stefan Tenbohlen, Ruben Grund, and Thomas Klein. Simulation of UHF PD wave propagation in plug-in cable terminations. 547-550, 2008. [PUMA: UHF PD propagation plug-in terminations cable wave] URL

Sebastian Coenen, Stefan Tenbohlen, Sacha Markalous, and T. Strehl. Sensitivity of UHF PD Measurements in Power Transformers. IEEE Transactions on Dielectrics and Electrical Insulation, (15)6:1553-1558, 2008. [PUMA: Sensitivity UHF PD Measurements Transformers Power]

Sebastian Coenen, Stefan Tenbohlen, Sacha Markalous, and T. Strehl. Sensitivity of UHF PD measurements. 2008. [PUMA: Sensitivity UHF PD measurements] URL

Sebastian Coenen, Stefan Tenbohlen, Sacha Markalous, and T. Strehl. Sensitivity Limits of UHF PD Measurements on Power Transformers. 2009. [PUMA: Sensitivity UHF PD Measurements Transformers Limits Power] URL

Alexander Troeger, Uwe Riechert, Simon Burow, and Stefan Tenbohlen. Sensitivity Evaluation of Different Types of PD Sensors for UHF-PD-Measurements. 2010. [PUMA: PD-Measurement Sensitivity UHF Sensors] URL

Chandra Prakash Beura, Michael Beltle, Stefan Tenbohlen, and Martin Siegel. Quantitative Analysis of the Sensitivity of UHF Sensor Positions on a 420 kV Power Transformer Based on Electromagnetic Simulation. Energies 2020, (13)32020. [PUMA: Transformer Simulationsend:unibiblio kV 420 Analysis Sensitivity UHF Electromagnetic Quantitative Positions Sensor Based Power]

Chandra Prakash Beura, Michael Beltle, Stefan Tenbohlen, and Martin Siegel. Quantitative Analysis of the Sensitivity of UHF Sensor Positions on a 420 kV Power Transformer Based on Electromagnetic Simulation. Energies 2020, December 2019. [PUMA: transformers monitoring sensors tests UHF PD acceptance evaluation positioning sensor power sensitivity discharge partial] URL

Sebastian Coenen, Martin Siegel, Michael Beltle, Stefan Tenbohlen, Stefan Hoek, P. Fehlmann, R. Schwarz, T. Linn, U. Kempf, M. Weber, and Jitka Fuhr. Proposal of a Calibration Methodology of UHF Partial Discharge Measurements for Power Transformers. 2020. [PUMA: a Measurements Methodology Calibration for Discharge UHF Partial Transformerssend:unibiblio of Proposal Power]