Evaporator Temperature Control of a Solar-Powered Adsorption Façade System. 2024. [PUMA: Adsorption Control Evaporator Façade Solar-Powered System Temperature a of]
Temperature Reduction as Operando Performance Recovery Procedure for Polymer Electrolyte Membrane Fuel Cells. 2024. [PUMA: Cells Electrolyte Fuel Membrane Operando Performance Polymer Procedure Recovery Reduction Temperature as for]
Adjusting the microstructure of additively manufactured parts with tailored temperature fields by the combination of powder bed fusion with cw-laser and ablation with ultrashort laser pulses. In Bo Gu, and Hongqiang Chen (Eds.), Laser 3D Manufacturing XI, (12876)SPIE, March 2024. [PUMA: Heat-dissipatingStructures myown Heat-dissipatinStructures PBF-LB/M Heat-dissipating Ablation Solidification USP with Simulation Additive AdditiveManufacturing of AlSi10Mg field structures UltrashortPulse manufacturing Microstructure temperature] URL
Development of a Multi-Sensor Concept for Real-Time Temperature Measurement at the Cutting Insert of a Single-Lip Deep Hole Drilling Tool. Applied sciences, (12)14:7095, MDPI, 2022. [PUMA: cel measurement sensor simulation sld temperature]
Hülle mit vielen Aufgaben - Textilfassade. Fassadentechnik, (23)6:20--25, 2017. [PUMA: (Planer), Anforderung, Aussichtsplattform, Baden-Württemberg, Baugrundeigenschaft, Befestigungselement, Belastungssimulation, Besonderheit, Betonkonstruktion, Betonplatte, Bundesrepublik, Dauerfestigkeit, Deutschland, Erdbebensimulation, Fassadengestaltung, Fassadenverkleidung, Flächengebilde, Funktion, Gebäudehülle, Glasfasergewebe, Krafteinleitung, Nachweis, Pendel, Planungsanforderung, Rottweil(11), Schwerlastanker, Schwingungsdämpfung, Schwingungserregung, Sobek, Stahlbetonturm, Temperaturspannung, Testanlage, Textiles Tragwerksbemessung, Turmbauwerk, Werner Windbelastung, Witterungsschutz anchor, application, area-measured building capacity, concrete damping, design, dimensioning earthquake endurance, facade facing, fastener, feature, force function, glass-fiber ground heavy-load impulse, installation, load loading material, of oscillatory pendulum, planning platform, proof, property, protection, reinforced requirement, shape, simulation, slab, sobek special stress, structure, structures, temperature test textile tissue, tower tower, vibration viewing weathering wind]
Performance assessment of top-oil temperature models for overload capability estimation in online monitoring purposes.. October 2021. [PUMA: Performance assessment capability estimation for in models monitoring of online overload purposes. temperature top-oil]
The facade and roofing system that is ventilating in dry conditions and enclosing in humid weather. 1-6, Industrial Property Office in Prague, 2019. [PUMA: building climate envelope facade humidity myown pine relative responsive temperature wood] URL
Structure of laminar premixed flames of methane near the auto-ignition limit. Combustion and Flame, (160)12:2770--2782, December 2013. [PUMA: Auto-ignition,Freely burning combustion,Ignition delay dependency flames,High planar propagating temperature time,Laminar velocity,Pressure]
IN-PROCESS MEASUREMENT AND NUMERICAL DETERMINATION OF THE TEMPERATURE IN THE CONTACT ZONE DURING SINGLE LIP DEEP HOLE DRILLING. In MM Science Journal (Eds.), MM Science Journal, 3:4556-4562, 2021. [PUMA: ifw measurement myown process temperature]
Temperature Distribution in Windings of Transformers with natural Oil circulation_. 2002. [PUMA: Distribution Oil Temperature Transformers Windings circulation natural] URL
Temperature Distribution in Windings of Transformers with natural Oil circulation. 2002. [PUMA: Distribution Oil Temperature Transformers Windings circulation natural] URL
A New Method for the Calculation of the Hot-Spot Temperature in Power Transformers With ONAN Cooling. IEEE Transactions on Power Delivery, (18)4:1284-1292, October 2003. [PUMA: Hot-spot factors modeling power temperature thermal transformerthermal] URL
Asset Management Based on Improved Online Monitoring Systems Applied to a 110/380 kV Substation. 2003. [PUMA: Acoustic Asset-Management Electric Hot-spot Managementdecision-making PD Power Transfer discharge function monitoring online partial system temperature] URL
Monitoring System of Large Power Transformers based on up-to-date Information Technology. 2004. [PUMA: Field Fuzzy Hot-spot Overloadcapability Paper/Oil-insulation Power Thermal Transformer ageing bus controlled fan monitoring operation technology temperature] URL
New Developments in Transformer Cooling Calculation. 2004. [PUMA: Power Transformers cooling heat rise temperature transfer winding] URL
Improved Top-oil Temperature Model for Unsteady-State Conditions of Power Transformers. 2005. [PUMA: Conditions Model Power Temperature Top-oil Transformers Unsteady-State] URL
Investigation of Different Top-oil Temperature Models for On-line Monitoring System of Power Transformer. 2006. [PUMA: Models Monitoring On-line Power System Temperature Top-oil Transformer]
Improved Monitoring of Dissolved Transformer Gases on the Basis of a Natural Internal Standard (NIS). 2007. [PUMA: DGA EGS NIS Oil TGM equilibrium extraction gas light sampling state temperature] URL
Prediction of the Oil Flow and Temperature Distribution in Power Transformers by CFD. 2010. [PUMA: CFD Distribution Flow Oil Power Temperature Transformers]
Experimental Investigation of the Temperature Distribution within the Low Voltage Winding of a Large Power Transformer. 2012. [PUMA: Distribution Large Low Power Temperature Transformer Voltage Winding]